Digital 4 Channel EMG Machine/EP System PC Based Evoked potential

 

Brief introduction

 

Introduction:

The equipment records bioelectricity activity of nerve muscle for determining its function state, which combines with nerve conduction speed, to give patient an auxiliary diagnosis.

Checking contents: EMG(electromygram), MCS(motor nerve conductor velocity), SCS(sensory nerve conductor velocity), F wave, Hreflex, RNS(repetitive nerve stimulation), Blink Reflex, VEP(visual evoked potential), BAEP(brainstem auditory evoked potential), SEP(somatosensory evoked potential), etc.


Features:


Professional EMG/EP operation platform and perfect test items, complete each test in the shortest time.

Neuro and muscle navigation system, convenient in selecting test part.

Powerful normal values system, contrast with normal data automatically.

Flexible software design, configure system parameters according to requirements.

High-speed data collection, electromagnetic interference suppression, Photoelectric isolation and low noise.

Integrative hardware system, compact in configuration and easy in moving.


Performance:


Main system part 

A/D conversion resolution 16 Bit

Sampling ratio 200kHz

Analysis time 5-5000ms

Stimulating frequency 0.1-50Hz


Amplifier part

Four-channel 

Sensitivity 0.05μV-20mV/Grid

Earth noise EMG <= 4μV(Vpp)

EP <=0.1μV(Vpp) (1000 times in average)

Common-mode rejection ratio >= 100dB


50Hz Ban wave setting:

Upper limit for Filter-frequency 20kHz

Lower limit for Filter-frequency 1Hz

Gain amplifies 25 times-400000 times


Stimulator part

Constant current 0.2-100mA

Pulse width 50-1000μS

Short circuit and overloading protection


Auditory Stimulator 

Stimulation wave 40Hz Short, Sound Stim

Stimulation polarity nondense wave, dense wave and alternant wave.

Sound strength 40-120db (5db per level) 

Stimulation mode left, right, left & right

Frequency of 40Hz carrier wave 500-8000Hz


Visual stimulator 

Mode tessellation, horizontal bar and vertical bar.

Stimulation view all-view, half-view and quarter-view

Resolution 3x4, 6x8, 12x16, 24x32, 48x64

Flash stimulator all quench,left light,right light,l&r light


Physical characteristic:


Dimension 420mm*350mm*46mm(L×W×H)

Net weight 6KG


Accessories:


 Disk

Power Cord

Power Adapter

USB Cable

Audio Cable 

Earth Cable

Current Stimulator

One-off Bipolar Needle Electrode D039035408, 0.35*40mm, D039060706, 0.60*70mm

Reuseable Bipolar Needle Electrode R039035408, 0.35*40mm, R039060706, 0.60*70mm

Concentric Needle Connecting Wire

1mm Connecting Lead Wire

 Disc Electrode

 Ring Electrode

 Surface Electrode

 Ground Electrode(Include lead cable)

 One-off Unipolar Needle Electrode

 From 1 to 2 Conversion Cable

 Surface Electrode Conversion Cable

Fuse 0.1A/250V, 5*20mm

Fuse F1.6AL250V, 5*20mm

Flash Stimulator